teknium1 9f78424dbb test(install-e2e/windows): capture the packaged launch of a PM-launched hermes desktop
`windows: * -> hermes-desktop-app-update (HEAD -> NEXT)` failed with
"a launch was actually captured (exit 0 without a launch must not pass)":
`hermes desktop` built the app and launched the real Hermes.exe, and the
driver's hook never saw it. There were two gaps, and either one alone is
enough to miss the launch:

- HEAD installs publish the PM launcher (.hermes\bin\hermes.exe), which
  runs its interpreter with -I and drops PYTHONPATH, so sitecustomize never
  loads. windows-e2e.ps1 now does what installer-script-e2e.sh already does:
  run launch-capture/pm-launch.py for a PM launcher, and keep PYTHONPATH
  for pre-PM venv console scripts.
- Since 3ddf82fe24 the Windows packaged launch is a detached
  subprocess.Popen, not subprocess.run. sitecustomize now also intercepts a
  launch-shaped Popen: it records the same spec and stands in for a child
  that already exited with 0. Every other Popen, including the one inside
  subprocess.run, spawns for real.
2026-09-27 04:15:09 -07:00
..