Review: the post-@dataclass property install and the undeclared __dict__ key hid the storage. _status_adapter_pinned is a real field and the resolving property lives in the class (as _UpdateTarget's does); test constructors pass the pinned field. No behaviour change.
131 lines
6.7 KiB
Python
131 lines
6.7 KiB
Python
"""Per-turn context shared between ``GatewayRunner._run_agent_inner`` and ``TurnRunner``.
|
|
|
|
Each ex-closure local is a field, written once by ``_run_agent_inner`` while wiring the turn.
|
|
``message`` (ex-``nonlocal``) is the only rebindable field; other mutable state uses
|
|
single-element lists so mutation stays visible to the outer body.
|
|
"""
|
|
|
|
from __future__ import annotations
|
|
|
|
from dataclasses import dataclass, field
|
|
from typing import Any, Callable, List, Optional
|
|
|
|
from agent.session_activity import AwakeIdleMeter
|
|
|
|
|
|
@dataclass
|
|
class TurnContext:
|
|
# read-only turn identity / wiring
|
|
source: Any = None
|
|
reply_expected: Optional[bool] = None
|
|
# Scheduled heartbeats are proactive work, not replies to the source message that
|
|
# registered the watch. Their routine delivery surfaces stay quiet.
|
|
scheduled_heartbeat: bool = False
|
|
_run_still_current: Callable[[], bool] = None # type: ignore[assignment]
|
|
_live_status_adapter: Any = None
|
|
_live_status_mode: str = "off"
|
|
_thinking_enabled: bool = False
|
|
progress_mode: str = "off"
|
|
progress_grouping: str = "grouped"
|
|
tool_progress_enabled: bool = False
|
|
progress_queue: Any = None
|
|
log_queue: Any = None
|
|
# mutable single-element containers (shared with the outer body)
|
|
last_progress_msg: list = field(default_factory=lambda: [None])
|
|
last_tool: list = field(default_factory=lambda: [None])
|
|
last_was_terminal_block: list = field(default_factory=lambda: [False])
|
|
repeat_count: list = field(default_factory=lambda: [0])
|
|
long_tool_hint_fired: list = field(default_factory=lambda: [False])
|
|
agent_holder: list = field(default_factory=lambda: [None])
|
|
# Turn-scoped so the poll loop and stale-agent eviction both discount host sleep from idle.
|
|
awake_idle: AwakeIdleMeter = field(default_factory=AwakeIdleMeter)
|
|
_LONG_TOOL_THRESHOLD_S: float = 30.0
|
|
_cleanup_progress: bool = False
|
|
_cleanup_adapter: Any = None
|
|
_cleanup_msg_ids: list[str] = field(default_factory=list)
|
|
_progress_metadata: Optional[dict] = None
|
|
_progress_reply_to: Optional[Any] = None
|
|
message: Optional[str] = None # the only rebindable field
|
|
# turn parameters / config snapshots (read-only in run_sync)
|
|
history: Any = None
|
|
context_prompt: Optional[str] = None
|
|
channel_prompt: Optional[str] = None
|
|
session_id: Optional[str] = None
|
|
session_key: Optional[str] = None
|
|
run_generation: Optional[int] = None
|
|
process_task_id: str = ""
|
|
process_baseline: frozenset[str] = field(default_factory=frozenset)
|
|
_interrupt_depth: int = 0
|
|
event_message_id: Optional[str] = None
|
|
# Raw inbound platform id (not the event_message_id reply anchor); stamped on the user turn.
|
|
inbound_message_id: Optional[str] = None
|
|
moa_config: Optional[dict] = None
|
|
title_user_message: Optional[str] = None
|
|
persist_user_message: Optional[Any] = None
|
|
persist_user_timestamp: Optional[float] = None
|
|
# display_kind of the persisted user row for a self-injected turn; DB-only, never sent.
|
|
# "internal_notification" for async-delegation/background notifications (#82888).
|
|
persist_user_display_kind: Optional[str] = None
|
|
persist_user_display_metadata: Optional[dict] = None
|
|
user_config: Any = None
|
|
mute_notification_reply: bool = False
|
|
voice_turn: bool = False # a voice-note turn: runs on auxiliary.voice_chat
|
|
enabled_toolsets: Any = None
|
|
disabled_toolsets: Any = None
|
|
log_mode_enabled: bool = False
|
|
# The chat's resolved display.interim_assistant_messages. Turn-shaped gates (scheduled heartbeat, hold_stream,
|
|
# finite viewer) apply in TurnRunner; a fresh agent's delegation.gateway_mode reads this session-shaped value.
|
|
interim_assistant_messages_enabled: bool = False
|
|
needs_progress_queue: bool = False
|
|
AIAgent: Any = None
|
|
resolve_display_setting: Any = None
|
|
result_holder: list = field(default_factory=lambda: [None])
|
|
tools_holder: list = field(default_factory=lambda: [None])
|
|
stream_consumer_holder: list = field(default_factory=lambda: [None])
|
|
streaming_tts_consumer_holder: list = field(default_factory=lambda: [None])
|
|
# voice-ack wiring
|
|
_voice_ack_fired: list = field(default_factory=lambda: [False])
|
|
_voice_ack_guild: list = field(default_factory=lambda: [None])
|
|
_voice_ack_loop: Any = None
|
|
# hook / status bridge wiring
|
|
_loop_for_step: Any = None
|
|
_hooks_ref: Any = None
|
|
# Read through the ``_status_adapter`` property: the pinned adapter answers only when the
|
|
# resolver (the runner's delivery lookup for this turn's source) finds none registered.
|
|
_status_adapter_pinned: Any = None
|
|
_status_adapter_resolver: Optional[Callable[[], Any]] = None
|
|
_status_chat_id: Any = None
|
|
_status_thread_metadata: Optional[dict] = None
|
|
# bound TurnRunner callbacks read via ctx
|
|
progress_callback: Optional[Callable] = None
|
|
voice_ack_callback: Optional[Callable] = None
|
|
_step_callback_sync: Optional[Callable] = None
|
|
_event_callback_sync: Optional[Callable] = None
|
|
_status_callback_sync: Optional[Callable] = None
|
|
# Slack-native task cards (opt-in); ID-bearing callbacks correlate start/complete by call ID
|
|
# --- Slack-native task-card progress (opt-in; #29483) ------------------ True when the Slack adapter's
|
|
# ``native_task_cards_enabled()`` opt-in is set for this turn's platform. The ID-bearing lifecycle
|
|
# callbacks are published by TurnRunner (like voice_ack_callback above) so tool starts and completions
|
|
# correlate by real tool-call ID instead of tool name.
|
|
_native_slack_task_cards: bool = False
|
|
native_tool_start_callback: Optional[Callable] = None
|
|
native_tool_complete_callback: Optional[Callable] = None
|
|
|
|
@property
|
|
def _status_adapter(self) -> Any:
|
|
"""The adapter that answers the turn NOW. A reconnect replaces the platform's adapter while a
|
|
turn runs, and the retired instance has no bot, so an approval card, clarify question or status
|
|
sent through the adapter pinned at turn start fails "Not connected" and the gated command waits
|
|
out its full timeout (#138133). The pinned one answers while no adapter is registered (the
|
|
reconnect gap), where its own send() still waits for the replacement."""
|
|
live = self._status_adapter_resolver() if self._status_adapter_resolver is not None else None
|
|
return live if live is not None else self._status_adapter_pinned
|
|
|
|
@_status_adapter.setter
|
|
def _status_adapter(self, adapter: Any) -> None:
|
|
self._status_adapter_pinned = adapter
|
|
|
|
def bind_status_adapter(self, resolve: Callable[[], Any]) -> None:
|
|
"""Pin the adapter that answers the turn now, and keep *resolve* to re-ask at every send."""
|
|
self._status_adapter_pinned, self._status_adapter_resolver = resolve(), resolve
|