"""Startup gate for the Chronos fire webhook (``POST /api/cron/fire``).
A backend that stops the guest on sleep wakes the agent FOR the fire, so the fire reaches the webhook in
the first second of a cold boot. The api_server adapter listens before the gateway has published any
adapter into ``runner.adapters`` (an adapter is registered only after its ``connect()`` returns), so a
fire taken then ran its job with no live adapters and a relay-fronted platform failed with "has no live
gateway transport" (the result was lost). Wait for the gateway to finish starting instead.
"""
from __future__ import annotations
import asyncio
from contextlib import suppress
from typing import Any, Optional
from aiohttp import web
# How long a fire may spend in the handler (token verify included) before a still-starting gateway is
# refused as retryable. Kept under the dashboard forwarder's 10s timeout: past it NAS sees a 503 while
# this handler still runs the job, and the retry would run it twice.
FIRE_STARTUP_WAIT_SECONDS = 7.0
_POLL_SECONDS = 0.1
def runner_is_draining(runner: Any) -> bool:
"""Whether ``runner`` refuses new work (an in-process drain, or one an external supervisor started)."""
return bool(getattr(runner, "_draining", False) or getattr(runner, "_external_drain_active", False))
async def refuse_until_started(runner: Any, job_id: str, *, received_at: float) -> Optional[web.Response]:
"""None once ``runner`` has finished starting (``_running``: every platform connect attempted and its
adapters published), or when there is no runner to ask (a self-hosted api_server, a test double).
Otherwise the retryable 503, worded like the dashboard's own "gateway unreachable" so NAS classifies
it the same, with the dashboard's 60s Retry-After (``_CRON_FIRE_RETRY_AFTER_SECONDS``).
``received_at`` is the loop time the handler was entered: time already spent verifying the token
counts against the budget."""
if runner is None:
return None
loop = asyncio.get_running_loop()
deadline = received_at + FIRE_STARTUP_WAIT_SECONDS
while True:
# Re-checked after every poll: the handler's drain check ran before this wait, and a gateway that
# starts draining meanwhile (a restart keeps _running True; a stop mid-boot never sets it) must not
# claim the fire.
draining = runner_is_draining(runner)
if not draining and getattr(runner, "_running", True):
return None
if draining or loop.time() >= deadline:
return web.json_response(
{"error": "gateway unreachable; retry", "job_id": job_id}, status=503, headers={"Retry-After": "60"})
await asyncio.sleep(_POLL_SECONDS)
async def live_adapters_once_started(
api_adapter: Any, request: web.Request, job_id: str, *, received_at: float,
) -> tuple[Optional[web.Response], Any]:
"""``(refusal, adapters)`` for a fire: the startup gate's retryable 503, else the gateway's LIVE adapters
(parity with the built-in ticker: E2EE / relay-fronted platforms have no native credential, so without
them delivery fails). ``None`` adapters when there is no runner (a self-hosted api_server)."""
runner = api_adapter.gateway_runner or request.app.get("gateway_runner")
if runner is None:
with suppress(Exception):
from gateway.run import _gateway_runner_ref
runner = _gateway_runner_ref()
refusal = await refuse_until_started(runner, job_id, received_at=received_at)
return refusal, (getattr(runner, "adapters", None) or None)