Review finding "Cleanup repeats weaker process checks" (Greptile P2 + independent review W1): the
smoke's gateway stop trusted the probe home's gateway.pid record (kind + home) and signalled whatever
process held that PID, so a live non-gateway process or a recycled PID named by a stale record was
terminated. Resolve the PID with gateway.status.live_gateway_pid_for_home (start-time reuse guard,
gateway command line, home ownership) and do nothing on a miss; psutil binds the create time so
terminate() refuses a PID reused in between. The driver puts --hermes-repo first on sys.path so the
check comes from the tree under test.