session's model_config, but the managed-worker sidecar allowlist only knew the runway key. Every worker turn's runway clear (both keys) was refused as invalid_params, which poisoned the worker store and failed the turn (tests/gateway/test_surface_admission.py managed-worker case, CI 1/3). Add the key to SIDECAR_KEYS; the worker-context test now restores and clears both keys through the worker store.