Teknium 6802b44be8 fix: disclose a wake-hidden fallback on the next user turn, quiet wake recovery lines
Review findings on the wake-turn notice skip.

A quota or billing failure keeps the fallback serving for a cooldown, so the
next turn the user sends makes no new switch: after a switch hidden on a wake
turn, the user's turn ran on the backup with no notice at all. The hidden notice
is now held; the next non-wake turn announces it before it runs if the fallback
is still serving, and drops it if the primary came back (the user never saw it
leave).

The turn-start "Primary model restored" line also fired on wake turns, so each
wake during an outage restored, re-failed and posted it again. It is now skipped
on wake turns and for a switch the user never saw. The restore line moves into
agent/fallback_notice.py beside the switch notice.

The test now drives real run_conversation turns against a loopback provider
(primary 402, backup streaming): two wakes, then a user turn, and a wake after
the cooldown. Both cases fail on main and on the previous head.
2026-11-17 02:08:41 -08:00

139 lines
7.5 KiB
Python

"""The user-visible fallback-switch notice: why the picked model could not respond, and when it is shown.
The fallback walk (``chat_completion_helpers.try_activate_fallback``) builds one line per switch and
shows it at the switch, before the fallback model is called, so the user sees which model is answering
while the turn runs. The error handler that classified the failure records the provider's own words on
``agent._fallback_trigger``; the switch for that same reason quotes them, redacted and truncated.
"""
from __future__ import annotations
import logging
from agent.error_classifier import FailoverReason
logger = logging.getLogger(__name__)
_FALLBACK_REASON_LABELS = {
FailoverReason.auth: "authentication failed",
FailoverReason.auth_permanent: "authentication permanently failed",
FailoverReason.billing: "billing or quota exhausted",
FailoverReason.rate_limit: "rate limit",
FailoverReason.upstream_rate_limit: "upstream model rate limit",
FailoverReason.overloaded: "provider overloaded",
FailoverReason.server_error: "provider server error",
FailoverReason.timeout: "request timeout",
FailoverReason.ssl_cert_verification: "TLS certificate verification failed",
FailoverReason.context_overflow: "context window exceeded",
FailoverReason.payload_too_large: "request payload too large",
FailoverReason.image_too_large: "image payload too large",
FailoverReason.model_not_found: "model not found",
FailoverReason.provider_policy_blocked: "provider policy blocked the request",
FailoverReason.content_policy_blocked: "content policy blocked the request",
FailoverReason.format_error: "request format rejected",
FailoverReason.role_alternation: "adjacent same-role messages rejected",
FailoverReason.invalid_encrypted_content: "encrypted reasoning state rejected",
FailoverReason.multimodal_tool_content_unsupported: "multimodal tool content unsupported",
FailoverReason.thinking_signature: "thinking signature rejected",
FailoverReason.long_context_tier: "long-context tier unavailable",
FailoverReason.oauth_long_context_beta_forbidden: "OAuth long-context beta unavailable",
FailoverReason.llama_cpp_grammar_pattern: "grammar pattern rejected",
FailoverReason.unknown: "provider failure",
}
_FALLBACK_DETAIL_MAX_CHARS = 200
def fallback_reason_text(reason: FailoverReason | None) -> str:
"""Return a concise operator-facing explanation for a fallback switch."""
label = _FALLBACK_REASON_LABELS.get(reason)
return label or str(getattr(reason, "value", None) or reason or "provider failure").replace("_", " ")
def record_fallback_trigger(agent, reason: FailoverReason | None, error_text: str) -> None:
"""Remember the provider's words for the switch this failure may cause. Masked here, while the
failing route's credentials are still on the agent: a provider echoing an opaque key back
(``Credential <key> rejected``) is caught by value, which pattern masking alone can miss."""
from agent.credential_pool_errors import redact_error_text
known = (getattr(agent, "api_key", None), getattr(agent, "_anthropic_api_key", None))
agent._fallback_trigger = (reason, redact_error_text(str(error_text or ""), known))
def fallback_trigger_text(agent, reason: FailoverReason | None) -> str:
"""The reason label plus the provider's own error. The error handler that classified the failure
stashes ``(reason, summary)`` on ``_fallback_trigger``; it is used once, and only by a switch for
that same reason, so an empty-response or truncation switch never borrows an older error."""
label = fallback_reason_text(reason)
stashed = getattr(agent, "_fallback_trigger", None)
agent._fallback_trigger = None
if not (isinstance(stashed, tuple) and len(stashed) == 2 and reason is not None and stashed[0] == reason):
return label
from agent.redact import redact_sensitive_text
detail = " ".join(redact_sensitive_text(str(stashed[1] or "")).split())
if not detail:
return label
if len(detail) > _FALLBACK_DETAIL_MAX_CHARS:
detail = detail[:_FALLBACK_DETAIL_MAX_CHARS - 1].rstrip() + "…"
return f"{label}: {detail}"
def fallback_notice_hidden(agent) -> bool:
"""A background wake turn (a completed process, a plugin's scheduled check: no user message) shows
no switch notice. Most of those turns end silent, and the notice is posted before anyone knows,
so during an outage every wake would post one into the chat. The kind is known at turn start,
so a turn the user sent still gets its notice before the fallback answers."""
from gateway.response_filters import is_machinery_display_kind
return is_machinery_display_kind(getattr(agent, "_turn_display_kind", None))
def surface_hidden_fallback(agent) -> None:
"""Turn-start reconciliation of a switch a wake turn did not show (call after the primary-restore
attempt). The fallback still serving (a quota cooldown keeps it across turns): the next turn the
user watches announces the held notice before it runs, so a hidden switch is never an
undisclosed one. The primary back: the user never saw it leave, so the held notice is dropped."""
held = getattr(agent, "_hidden_fallback_notice", None)
if not held or fallback_notice_hidden(agent):
return
agent._hidden_fallback_notice = None
if getattr(agent, "_provider_fallback_active", False):
announce_fallback_switch(agent, held)
def announce_primary_restored(agent, previous_model: str, previous_provider: str) -> None:
"""The recovery line after a turn-start restore. None for a switch the user never saw (hidden
on a wake turn), and none on a wake turn: during an outage each wake would restore, re-fail and
post it again."""
unseen = getattr(agent, "_hidden_fallback_notice", None)
agent._hidden_fallback_notice = None
if unseen or fallback_notice_hidden(agent):
return
try:
agent._emit_diagnostic_status(
f"✅ Primary model restored: {agent.model} via {agent.provider}; "
f"fallback {previous_model} via {previous_provider} is no longer active.")
except Exception: # health: allow BLE001 -- a surface failure must never undo a successful restore
logger.debug("primary restored notice failed to emit", exc_info=True)
def announce_fallback_switch(agent, notice: str) -> None:
"""Show the switch now, before the fallback model starts answering: the user must see which
model this turn runs on while it runs, not after it ends. Display-only (status rail), so the
cached prompt is untouched; it obeys the muted-warnings setting like every diagnostic. Not
buffered with the retry chatter, so a terminal-failure flush cannot repeat it.
Its own ``fallback`` kind: messaging adapters edit one status message per kind in a turn, so on
the shared ``lifecycle`` kind the next retry or re-prompt line replaced it (Telegram)."""
if fallback_notice_hidden(agent):
logger.info("fallback switch notice not shown on a background wake turn: %s", notice)
agent._hidden_fallback_notice = notice
return
agent._hidden_fallback_notice = None
from gateway.warning_notifications import DiagnosticText
try:
agent._emit_status_kind(FALLBACK_STATUS_KIND, DiagnosticText(notice), origin="fallback_switch")
except Exception: # health: allow BLE001 -- a surface failure must never fail the switch itself
logger.debug("fallback switch notice failed to emit", exc_info=True)
FALLBACK_STATUS_KIND = "fallback"